contact us
Leave Your Message
Products Categories
Featured Products

Products

Omron CJ-series PLC Module I/O Interface Unit CJ1W-II101Omron CJ-series PLC Module I/O Interface Unit CJ1W-II101
01

Omron CJ-series PLC Module I/O Interface Unit CJ1W-II101

2024-12-27

Expand CJ/NJ-series with These Units

• Rack-mountable Units enable expanding Controller capacity even when space is limited.
• Easy-to-use connectors enable quick expansion without any settings.

view detail
Omron CJ-series Special I/O Unit High-speed Counter Unit CJ1W-CT021Omron CJ-series Special I/O Unit High-speed Counter Unit CJ1W-CT021
02

Omron CJ-series Special I/O Unit High-speed Counter Unit CJ1W-CT021

2024-12-27

High-Speed, Flexible Control With A Wide Array of Features

• Input frequencies to 500 kHz.
• 32-bit counting range.
• Digital variable noise filter provided.
• 5, 12, 24 V line driver inputs available.
• Supports simple, ring, and linear counting modes.

view detail
Omron High-speed Special I/O Units Position Control Units CJ1W-NC133Omron High-speed Special I/O Units Position Control Units CJ1W-NC133
03

Omron High-speed Special I/O Units Position Control Units CJ1W-NC133

2024-12-28

High-speed, High-precision positioning with 1, 2, or 4 axes

• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.

view detail
Omron High-speed Special I/O Units Position Control Units CJ1W-NC233Omron High-speed Special I/O Units Position Control Units CJ1W-NC233
04

Omron High-speed Special I/O Units Position Control Units CJ1W-NC233

2024-12-28

High-speed, High-precision positioning with 1, 2, or 4 axes

• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.

view detail
Omron CJ1 Special I/O Units Position Control Units CJ1W-NC433Omron CJ1 Special I/O Units Position Control Units CJ1W-NC433
05

Omron CJ1 Special I/O Units Position Control Units CJ1W-NC433

2024-12-28

High-speed, High-precision positioning with 1, 2, or 4 axes

• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.

view detail
Omron CJ-series PLC Module CJ1 CPU Bus Unit Ethernet Unit CJ1W-ETN21Omron CJ-series PLC Module CJ1 CPU Bus Unit Ethernet Unit CJ1W-ETN21
06

Omron CJ-series PLC Module CJ1 CPU Bus Unit Ethernet Unit CJ1W-ETN21

2024-12-28

Organically Connect the Production Site and Management

• Use Ethernet to implement various communications protocols.
• Implement FINS message communications using UDP/IP or TCP/IP with a user application on a host computer or with Support Software, such as the CX-Programmer.
• Use the clock on an SNTP server to automatically adjust the clocks in the PLCs connected to the Ethernet network. (An SNTP server is required separately.)

view detail
Omron CJ1 Basic I/O Units CJ-series Interrupt Input Units CJ1W-INT01Omron CJ1 Basic I/O Units CJ-series Interrupt Input Units CJ1W-INT01
07

Omron CJ1 Basic I/O Units CJ-series Interrupt Input Units CJ1W-INT01

2024-12-30

High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

• High-speed ON response of 0.05 ms
• Use up to 32 interrupt inputs with up to two Units per CPU Unit.
• Applicable with both NPN and PNP output devices. Polarity selection is not required. *
*The same polarity is used for the same common.

view detail
Omron Basic I/O Units CJ-series Quick-response Input Units CJ1W-IDP01Omron Basic I/O Units CJ-series Quick-response Input Units CJ1W-IDP01
08

Omron Basic I/O Units CJ-series Quick-response Input Units CJ1W-IDP01

2024-12-31

Capture Input Signals Shorter Than the Cycle Time

• A pulse width (ON time) of 0.05 ms min. can be read by the Quick-response Input Unit.
• Input data read by the internal circuits is cleared when inputs are refreshed.
• Quick-response Input Units can be used when communicating with inspection equipment to read the many pulse signals that are too short to
be read with normal I/O Units.

view detail
Omron CJ1 Isolated-type CJ-series Process Analog I/O Unit CJ1W-PTS15Omron CJ1 Isolated-type CJ-series Process Analog I/O Unit CJ1W-PTS15
09

Omron CJ1 Isolated-type CJ-series Process Analog I/O Unit CJ1W-PTS15

2024-12-31

A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)

• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input

view detail
Omron CJ-series Isolated-type Thermocouple Input Units CJ1W-PTS51Omron CJ-series Isolated-type Thermocouple Input Units CJ1W-PTS51
10

Omron CJ-series Isolated-type Thermocouple Input Units CJ1W-PTS51

2024-12-31

A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)

• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input

view detail
Omron Isolated-type Resistance Thermometer Input Units CJ1W-PTS52Omron Isolated-type Resistance Thermometer Input Units CJ1W-PTS52
11

Omron Isolated-type Resistance Thermometer Input Units CJ1W-PTS52

2024-12-31

A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)

• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input

view detail
Omron CJ1 Special I/O Units Isolated-type DC Input Units CJ1W-PDC15Omron CJ1 Special I/O Units Isolated-type DC Input Units CJ1W-PDC15
12

Omron CJ1 Special I/O Units Isolated-type DC Input Units CJ1W-PDC15

2025-01-02

A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)

• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input

view detail