Products
Omron High-speed CJ1 4 axes Position Control Units CJ1W-NC413
High-speed, High-precision positioning with 1, 2, or 4 axes
• Two types to choose from: open collector output and line driver. Because both open collector output and line driver types feature 1-, 2-, and 4-axis models, the most appropriate model can be selected for the application at hand.
• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.
Omron PLC Module CJ-series I/O Control Unit CJ1W-IC101
Expand CJ/NJ-series with These Units
• Rack-mountable Units enable expanding Controller capacity even when space is limited.
• Easy-to-use connectors enable quick expansion without any settings.
Omron CJ-series PLC Module I/O Interface Unit CJ1W-II101
Expand CJ/NJ-series with These Units
• Rack-mountable Units enable expanding Controller capacity even when space is limited.
• Easy-to-use connectors enable quick expansion without any settings.
Omron CJ-series Special I/O Unit High-speed Counter Unit CJ1W-CT021
High-Speed, Flexible Control With A Wide Array of Features
• Input frequencies to 500 kHz.
• 32-bit counting range.
• Digital variable noise filter provided.
• 5, 12, 24 V line driver inputs available.
• Supports simple, ring, and linear counting modes.
Omron High-speed Special I/O Units Position Control Units CJ1W-NC133
High-speed, High-precision positioning with 1, 2, or 4 axes
• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.
Omron High-speed Special I/O Units Position Control Units CJ1W-NC233
High-speed, High-precision positioning with 1, 2, or 4 axes
• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.
Omron CJ1 Special I/O Units Position Control Units CJ1W-NC433
High-speed, High-precision positioning with 1, 2, or 4 axes
• Positioning START occurs within 2 ms (maximum speed) after receiving a command from the Programmable Controller. (Refer to the Operation Manual for conditions.)
• High-speed data transfer is possible using INTELLIGENT I/O WRITE (IOWR) and INTELLIGENT I/O READ (IORD) instructions.
• Fine control from low to high speed (500 kpps max.) is possible in 1-pps units.
• Easy-to-Use positioning can be possible with versatile functions such as Teaching, Override, Backlash compensation, Zones, Forced interrupt and Acceleration/Deceleration curve.
Omron CJ-series PLC Module CJ1 CPU Bus Unit Ethernet Unit CJ1W-ETN21
Organically Connect the Production Site and Management
• Use Ethernet to implement various communications protocols.
• Implement FINS message communications using UDP/IP or TCP/IP with a user application on a host computer or with Support Software, such as the CX-Programmer.
• Use the clock on an SNTP server to automatically adjust the clocks in the PLCs connected to the Ethernet network. (An SNTP server is required separately.)
Omron CJ1 Basic I/O Units CJ-series Interrupt Input Units CJ1W-INT01
High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.
• High-speed ON response of 0.05 ms
• Use up to 32 interrupt inputs with up to two Units per CPU Unit.
• Applicable with both NPN and PNP output devices. Polarity selection is not required. *
*The same polarity is used for the same common.
Omron Basic I/O Units CJ-series Quick-response Input Units CJ1W-IDP01
Capture Input Signals Shorter Than the Cycle Time
• A pulse width (ON time) of 0.05 ms min. can be read by the Quick-response Input Unit.
• Input data read by the internal circuits is cleared when inputs are refreshed.
• Quick-response Input Units can be used when communicating with inspection equipment to read the many pulse signals that are too short to
be read with normal I/O Units.
Omron CJ1 Isolated-type CJ-series Process Analog I/O Unit CJ1W-PTS15
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron CJ-series Isolated-type Thermocouple Input Units CJ1W-PTS51
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input