Products
Omron Isolated-type Resistance Thermometer Input Units CJ1W-PTS52
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron CJ1 Special I/O Units Isolated-type DC Input Units CJ1W-PDC15
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron CJ-series Isolated-type Units with Universal Inputs CJ1W-AD04U
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron CJ1 Process Input Units Isolated-type Units CJ1W-PH41U
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron CJ1 CPU Bus Unit CJ-series DeviceNet Unit CJ1W-DRM21
Smallest in the Industry! A DeviceNet Unit for the CJ Series that Boasts Industry-leading Performance and Functions
• Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data.
• Can be used as both a master and a slave at the same time.
• Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using in combination with a Configurator.
• Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup.
Omron PLC Module CJ1 CPU Bus Unit CJ-series FL-net Unit CJ1W-FLN22
Connect to Multivendor Controller Networks
• Conforms to FL-net, a quickly spreading standard.
• FL-net is a multivendor FA network at the controller/machine level that is based on Ethernet. (It uses UDP/IP.)
• FL-net supports message transmissions and cyclic data transmissions. (Message transmissions are also possible using FINS communications.)
• A CJ-series PLC can be used to interface communications between Ethernet information networks, OMRON's Controller Link FA network, and
DeviceNet field bus.
Omron CJ1 Special I/O Unit CJ-series CompoNet Master Units CJ1W-CRM21
NJ/CJ-series CompoNet Master Units Increase the Range of Applicability of Sensors and Actuators.
• Setup is simple. Make the master's mode settings and set the baud rate, and you're ready to go.
• Control up to 2,560 points and 384 nodes with one Master Unit.
• Intuitive memory mapping with separate areas for Word Slave Units and Bit Slave Units.
• Seven-segment display helps with startup and enables prompt detection of problems
Omron Special I/O Units CJ Series Temperature Control Unit CJ1W-TC001
A Single Unit Performing All the Functions of 4 Temperature Controllers
• Built-in PID control with 2 or 4 control loops or ON/OFF control
• Direct input of 7 types of thermocouple or resistance thermometer
• 500 ms sampling cycle
• RUN/STOP control from CPU Unit
• Unrestricted CPU Unit cycle time
• Heater burnout detection
• Auto-tuning (AT) function
Omron CJ2M series CP32 module CJ2M-CPU32 PLC programming controller
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron Special I/O Units CJ Series Temperature Control Unit CJ1W-TC002
A Single Unit Performing All the Functions of 4 Temperature Controllers
• Built-in PID control with 2 or 4 control loops or ON/OFF control
• Direct input of 7 types of thermocouple or resistance thermometer
• 500 ms sampling cycle
• RUN/STOP control from CPU Unit
• Unrestricted CPU Unit cycle time
• Heater burnout detection
• Auto-tuning (AT) function
Omron CJ2M series PLC module unit programmable controller CJ2M-CPU33
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
Omron CJ2M series PLC Programmable Logic Controller module CJ2M-CPU11
A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5 V)
• Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
• Isolation between input channels prevents unwanted current paths between input channels.
• Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
• Process value alarm with two alarms for each input
